Entity Name: | QUAD CITY ENGINEERING COMPANY, INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Goodstanding |
Date Formed: | 18 Oct 1944 |
Company Number: | CORP_27936903 |
File Number: | 27936903 |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
JEFFREY L HAGMEIER, 3650 MORTON DR, EAST MOLINE, 61244, ROCK ISLAND | Agent | 2024-08-30 |
Name and Address | Role |
---|---|
JEFFREY L HAGMEIER 3650 MORTON DR EAST MOLINE 61244 | President |
Name and Address | Role |
---|---|
JEFFREY L HAGMEIER 3650 MORTON DR EAST MOLINE 61244 | Secretary |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMM | No data | Voting Rights | 1000 | 110000 | 100 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346200074 | 0524500 | 2022-09-07 | 3650 MORTON DRIVE, EAST MOLINE, IL, 61244 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1942714 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100178 L04 III |
Issuance Date | 2022-09-30 |
Current Penalty | 1243.0 |
Initial Penalty | 2486.0 |
Final Order | 2022-10-25 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about September 7, 2022, and at times prior, employees were operating powered industrial trucks and the employer had not ensured employees were being evaluated at least every three years. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100178 L06 |
Issuance Date | 2022-09-30 |
Current Penalty | 1243.0 |
Initial Penalty | 2486.0 |
Final Order | 2022-10-25 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about September 7, 2022, and at times prior, employees were operating powered industrial trucks and the employer had not certified that each operator had been trained and certified. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100184 E01 |
Issuance Date | 2022-09-30 |
Abatement Due Date | 2022-11-01 |
Current Penalty | 1243.0 |
Initial Penalty | 2486.0 |
Final Order | 2022-10-25 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.184(e)(1):Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: On or about September 7, 2022, employees were using alloy steel slings that did not have tags or tags were illegible in identifying size, grade, rated capacity and reach. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2022-09-30 |
Abatement Due Date | 2022-11-01 |
Current Penalty | 2900.5 |
Initial Penalty | 5801.0 |
Final Order | 2022-10-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc: On or about September 7, 2022, employees working at the Amera-Seiki lathe were not provided with locking or interlocking doors to protect the employees from coming into contact with the rotating portion of the CNC lathe's chuck while employees manually polished metal parts in the CNC lathe. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19100242 B |
Issuance Date | 2022-09-30 |
Abatement Due Date | 2022-11-01 |
Current Penalty | 1657.5 |
Initial Penalty | 3315.0 |
Final Order | 2022-10-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about September 7, 2022, employees working at the Amera-Seiki lathe in the shop were using 100 p.s.i. compressed air to blow off parts and coolant and the employer had not ensured that the pressure was reduced to less than 30 p.s.i. |
Date of last update: 17 Feb 2025