345614945
|
0521400
|
2021-11-02
|
4 NATOMA, OAK BROOK, IL, 60521
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-11-02
|
Emphasis |
L: FALL, P: FALL, L: PIV
|
Case Closed |
2022-01-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2022-01-11 |
Current Penalty |
2100.0 |
Initial Penalty |
3218.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6):The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about November 2, 2021 an employee was operating a Rough Terrain Fork Truck prior to being trained and certified, exposing employees to the hazards associated with struck-by hazards and falls. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 A06 |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2021-12-27 |
Current Penalty |
2100.0 |
Initial Penalty |
3218.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(a)(6):Scaffolds were not constructed in accordance with the design by a qualified person: On or about November 2, 2021 a job made box (scaffold) was attached to the forks of a rough terrain fork truck. The scaffold was not constructed and designed by a qualified person, exposing an employee to a fall of over 20 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c). |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 IV |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2021-12-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(iv):Front-end loaders and similar pieces of equipment were used to support scaffold platforms without being specifically designed by the manufacturer for such use: Note: Preamble to Subpart L promulgated new paragraph (c)(2)(iv) & (v) in final rule to provide guidance. On or about November 2, 2021 employees used a Rough Terrain Fork Truck to support a scaffold platform (job made box), exposing the employee to a fall of over 20 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2021-12-27 |
Current Penalty |
1675.0 |
Initial Penalty |
2575.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii):Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: On or about November 2, 2021 an employee was not protected from falling through unguarded skylights, exposing the employee to falls greater that 6 feet in height. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2021-12-27 |
Current Penalty |
2900.0 |
Initial Penalty |
4505.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15):Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: On or about November 2, 2021, two workers were attached to one roof anchor, exposing employees to a fall hazard of 13 feet, as the roof anchor would not support 5,000 pounds per worker and was not installed per the manufacturers specifications. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-12-10 |
Abatement Due Date |
2021-12-27 |
Current Penalty |
6225.0 |
Initial Penalty |
9011.0 |
Final Order |
2022-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about November 2, 2021 an employee was not protected from a fall while engaged in residential roofing operations, exposing them to a 13 foot fall. Smart Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1291199, citation number 1, item number 3 and was affirmed as a final order on March 15, 2018, with respect to a workplace located at 322 Ogden Ave. Westmont, IL 60559. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
|
342911997
|
0521400
|
2018-01-30
|
322 OGDEN AVE., WESTMONT, IL, 60559
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-01-30
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-03-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260416 A01 |
Issuance Date |
2018-02-23 |
Abatement Due Date |
2018-03-09 |
Current Penalty |
5691.0 |
Initial Penalty |
5691.0 |
Final Order |
2018-03-15 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about January 30, 2018, employees performing roofing operations were exposed to an energized, un-insulated, overhead service drop, exposing employees to an electrical shock. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260502 H01 III |
Issuance Date |
2018-02-23 |
Abatement Due Date |
2018-03-09 |
Current Penalty |
5691.0 |
Initial Penalty |
5691.0 |
Final Order |
2018-03-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(1)(iii): The safety monitor was not on the same walking/working surface and within visual sighting distance of the employee being monitored. On or about January 30, 2018, the safety monitor was not on the same walking/working surface as the employees being monitored, exposing employees to a fall of 11.9 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 H01 V |
Issuance Date |
2018-02-23 |
Abatement Due Date |
2018-03-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: On or about January 30, 2018, employees performing roofing operations at a commercial building were exposed to a fall of 11.9 feet as the safety monitor had other duties. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2018-02-23 |
Abatement Due Date |
2018-03-09 |
Current Penalty |
12934.0 |
Initial Penalty |
28457.0 |
Final Order |
2018-03-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width: On or about January 30, 2018, employees performing roofing operations at a commercial building were not protected from a fall, exposing employees to a fall of 11.9 feet. Smart Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10) which was contained in OSHA violation number 900637, citation 2, item 1, issued on May 20, 2013, and became final order on or about June 4, 2013, with respect to a workplace located at 835 Pearson St., Des Plaines, IL 60016 Smart Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10) which was contained in OSHA violation number 312320492, citation 1, item 4a, issued on August 1, 2008, and became final order on or about August 21, 2008, with respect to a workplace located at 310 Green Bay Road, Winnetka, IL 60093. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d). |
|
|
339630816
|
0524200
|
2014-03-14
|
425 N. ASHLAND, PARK RIDGE, IL, 60068
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-14
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-12-09
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2014-04-22 |
Current Penalty |
1050.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Employees were exposed to head injury while working without protective helmets in areas below roofing work activities. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2014-04-22 |
Current Penalty |
1050.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) Employees were exposed to eye injury while operating an electric grinder to cut materials without the eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2014-04-22 |
Current Penalty |
1050.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-05-08 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) Fall protection anchor devices were not secured with a sufficient number of fasteners when installed through wood sheathing without being secured to trusses or support beams. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2014-04-22 |
Current Penalty |
1650.0 |
Initial Penalty |
2640.0 |
Final Order |
2014-05-08 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Employees were exposed to the hazard of free falling more than 6 feet and contacting lower level areas while using personal fall arrest systems that were not rigged to prevent these hazards. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
|
339006371
|
0524200
|
2013-04-15
|
835 PEARSON ST., DES PLAINES, IL, 60016
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-15
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2014-03-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260150 C01 VI |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-05-20 |
Current Penalty |
1056.0 |
Initial Penalty |
1760.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: a) A fire extinguisher was not provided where employees were using a 20 pound propane tank to fuel a roofing torch. No abatement certification or documentation is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B10 |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-05-31 |
Current Penalty |
3696.0 |
Initial Penalty |
6160.0 |
Final Order |
2013-06-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Employees engaged in roofing activities on a low-slope roof were exposed to falls from the edge of the roof of a five story building where fall protection or a combination of warning line systems and safety monitoring was not being used. Smart Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10) which was contained in OSHA violation number 312320492, citation 1, item 4a, issued on August 1, 2008, and became final order on or about August 21, 2008, with respect to a workplace located at 310 Green Bay Road, Winnetka, IL 60093. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |
|
|
334210648
|
0524200
|
2012-05-08
|
1505-1509 BROWN, DES PLAINES, IL, 60016
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-05-08
|
Emphasis |
L: FALL
|
Case Closed |
2012-06-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260552 A01 |
Issuance Date |
2012-05-09 |
Abatement Due Date |
2012-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-05-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications were not available, the limitations assigned to the equipment were not based on the determinations of a professional engineer competent in the field: a) Roofing materials were being used as counterweighting for a hand powered hoist being operated at the site. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B03 |
Issuance Date |
2012-05-09 |
Abatement Due Date |
2012-05-10 |
Current Penalty |
4000.0 |
Initial Penalty |
6160.0 |
Final Order |
2012-05-24 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: a) Employees were exposed to the hazard of falling approximately 25 feet while working in a hoist area and operating a hand powered hoist along the rear elevation of the building. b) Employees were exposed to the hazard of falling approximately 25 feet while working in a hoist area during the crane delivery of materials to the roof deck. Smart Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(3) which was contained in OSHA inspection number 312320492, citation 1, item 2, issued on August 1, 2008 and became final order on or about August 2, 2008. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |
|
|
330772914
|
0524200
|
2011-06-30
|
1006 CLIFTON, PARK RIDGE, IL, 60068
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-07-21
|
Emphasis |
L: FALL
|
Case Closed |
2011-08-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2011-07-21 |
Abatement Due Date |
2011-07-22 |
Current Penalty |
3000.0 |
Initial Penalty |
4620.0 |
Final Order |
2011-08-03 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) Employees were exposed to the hazard of falling while performing roofing work without the use of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |
|
|
314463654
|
0524200
|
2010-05-10
|
201 S. WE GO TRAIL, MT. PROSPECT, IL, 60056
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-05-11
|
Emphasis |
S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR, L: FALL
|
Case Closed |
2010-05-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2010-05-11 |
Abatement Due Date |
2010-05-17 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
03 |
|
|
312320492
|
0524200
|
2008-07-16
|
310 GREEN BAY ROAD, WINNETKA, IL, 60093
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-08-01
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2008-09-04
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
400.0 |
Initial Penalty |
1000.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B03 |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
800.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
400.0 |
Initial Penalty |
1000.0 |
Nr Instances |
6 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
800.0 |
Initial Penalty |
2000.0 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19260502 F01 III |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Nr Instances |
3 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260502 H02 |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
800.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260502 J07 I |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-07 |
Current Penalty |
400.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2008-08-01 |
Abatement Due Date |
2008-08-06 |
Current Penalty |
400.0 |
Initial Penalty |
1000.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
03 |
|
|
308732551
|
0524200
|
2005-04-05
|
424 MEACHAM AVE., PARK RIDGE, IL, 60068
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-04-19
|
Emphasis |
L: FALL
|
Case Closed |
2005-05-19
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260452 K01 |
Issuance Date |
2005-04-25 |
Abatement Due Date |
2005-04-28 |
Current Penalty |
200.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2005-04-25 |
Abatement Due Date |
2005-04-28 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2005-04-25 |
Abatement Due Date |
2005-04-28 |
Current Penalty |
250.0 |
Initial Penalty |
625.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B22 |
Issuance Date |
2005-04-25 |
Abatement Due Date |
2005-04-28 |
Current Penalty |
200.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 I |
Issuance Date |
2005-04-25 |
Abatement Due Date |
2005-04-28 |
Current Penalty |
800.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
308657766
|
0524200
|
2005-03-07
|
424 MEACHAM AVE., PARK RIDGE, IL, 60068
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-03-07
|
Emphasis |
L: FALL
|
Case Closed |
2005-03-07
|
|
307947895
|
0524200
|
2004-07-07
|
BEAVER CREEK #16, VERNON HILLS, VERNON HILLS, IL, 60061
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-07-20 |
Emphasis |
L: FALL |
Case Closed |
2004-07-26 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2004-07-20 |
Abatement Due Date |
2004-07-23 |
Current Penalty |
437.5 |
Initial Penalty |
625.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
03 |
|
|
307603118
|
0524200
|
2004-04-08
|
334 SHERIDAN RD., GLENCOE, IL, 60022
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-04-08 |
Emphasis |
L: FALL |
Case Closed |
2004-06-21 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2004-04-27 |
Abatement Due Date |
2004-05-03 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2004-04-27 |
Abatement Due Date |
2004-05-03 |
Current Penalty |
735.0 |
Initial Penalty |
1050.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
|
122498561
|
0524200
|
1995-05-15
|
8801 NORTH OLCOTT, NILES, IL, 60714
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1995-05-15 |
Emphasis |
L: FALL |
Case Closed |
1995-07-12 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
1995-06-09 |
Abatement Due Date |
1995-06-14 |
Current Penalty |
250.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
|