Entity Name: | FLUSH PLUMBING AND SEWER, INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Goodstanding |
Date Formed: | 19 May 1999 |
Company Number: | CORP_60501912 |
File Number: | 60501912 |
Type of Business: | All Inclusive Purpose |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
DARRON REEP, 929 QUINCE CT, MT PROSPECT, 60056, COOK-NOT IN CITY OF CHICAGO | Agent | 2005-05-31 |
Name and Address | Role |
---|---|
DARRON REED 929 QUINCE COURT MT. PROSPECT IL 60056 | President |
Name and Address | Role |
---|---|
LORI REED | Secretary |
Name | Type | Effective Date | Cancellation Date | Cancellation Type | Last Renewal Date |
---|---|---|---|---|---|
FLUSH SEWER SERVICE | Assume Name | 2003-06-18 | No data | No data | No data |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMMON | No data | Voting Rights | 1000 | 1000000 | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334302510 | 0524200 | 2012-05-15 | 8931 MARMORA, MORTON GROVE, IL, 60053 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2012-05-31 |
Current Penalty | 900.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-06-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Employees working in a trench were not wearing protective helmets where there was a possible danger of head injury from falling objects. No abatement certification or documentation is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2012-05-31 |
Abatement Due Date | 2012-06-01 |
Current Penalty | 900.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-06-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: a) Employees were not provided with a safe means of egress when working in a trench with a depth of approximately 6.1 feet. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2012-05-31 |
Abatement Due Date | 2012-06-01 |
Current Penalty | 900.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-06-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Employees were working in a trench where the spoil pile was placed and kept at the edge of the excavation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2012-05-31 |
Current Penalty | 1300.0 |
Initial Penalty | 2400.0 |
Final Order | 2012-06-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): a) Employees were not protected from the hazard of cave-in while working in a trench measuring approximately 6.1 feet in depth. No abatement certification or documentation is required for this item. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9659607105 | 2020-04-15 | 0507 | PPP | 929 QUINCE CT, MT PROSPECT, IL, 60056 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|