Search icon

KMA RESTORATION, INC.

Company Details

Entity Name: KMA RESTORATION, INC.
Jurisdiction: Illinois
Entity Type: Corporation - Domestic BCA
Status: Goodstanding
Date Formed: 28 Mar 2000
Company Number: CORP_60974012
File Number: 60974012
Type of Business: All Inclusive Purpose
Place of Formation: ILLINOIS

Agent

Name and Address Role Appointment Date
MAREK KOZIOL, 665 W BEL AIRE LN, MOUNT PROSPECT, 60056, COOK-NOT IN CITY OF CHICAGO Agent 2009-03-20

President

Name and Address Role
MAREK KOSIOL, 665 W BEL AIRE LN, MT PROSPECT 60056 President

Secretary

Name and Address Role
MARER KOZIOL, 665 W BEL AIRE LN, MT PROSPECT 60056 Secretary

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMMON No data Voting Rights 10000 1000000 1

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335423000 0524200 2012-07-25 3470 LAKESHORE DR., CHICAGO, IL, 60611
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-07-25
Emphasis L: FALL
Case Closed 2012-08-10
331090183 0524200 2011-11-15 901-905 CENTER ST., DES PLAINES, IL, 60018
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2011-11-15
Emphasis L: FALL
Case Closed 2013-09-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2011-11-29
Current Penalty 960.0
Initial Penalty 2400.0
Final Order 2011-12-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) Employees were exposed to electrical shock from unguarded live wires. No abatement certification or documentation is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 G01 II
Issuance Date 2011-11-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-12-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(1)(ii): Flexible cords were not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]: a) Flexible cords were not energized from a receptacle outlet. No abatement certification or documentation is required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260405 G02 III
Issuance Date 2011-11-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-12-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) Flexible cords being used to power electrical equipment were spliced directly into a breaker box. No abatement certification or documentation is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2011-11-29
Current Penalty 960.0
Initial Penalty 2400.0
Final Order 2011-12-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Employees were provided with electrial tools and equipment connected by cord and plug without the use of an assured equipment grounding conductor program or ground fault circuit interrupters (GFCI's). No abatement certification or documentation is required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2011-11-29
Current Penalty 1695.0
Initial Penalty 4200.0
Final Order 2011-12-08
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Employees performing masonry work were exposed to fall hazards from the roof of a 5 story building. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.