Entity Name: | COBALT CONSTRUCTION, INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Goodstanding |
Date Formed: | 15 Mar 2002 |
Company Number: | CORP_62102497 |
File Number: | 62102497 |
Type of Business: | All Inclusive Purpose |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
DINO KYPRIANIDIS, 4 W HIAWATHA TRL, MOUNT PROSPECT, 60056, COOK-NOT IN CITY OF CHICAGO | Agent | 2020-07-23 |
Name and Address | Role |
---|---|
DAWN KYPRIANIDIS 4 W HIAWATHATRAIL MOUNT PROSPECT IL, 60056 | Secretary |
Name and Address | Role |
---|---|
DINO KYPRIANIDIS 4 W HIAWATHATRAIL MOUNT PROSPECT IL, 60056 | President |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMMON | No data | Voting Rights | 2000 | 1000000 | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
333853232 | 0521400 | 2012-04-12 | 1S550 RT 83, OAK BROOK, IL, 60521 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 385246 |
Safety | Yes |
Type | Inspection |
Activity Nr | 331672 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260100 A |
Issuance Date | 2012-05-01 |
Abatement Due Date | 2012-05-08 |
Current Penalty | 0.0 |
Initial Penalty | 1200.0 |
Final Order | 2012-05-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. On April 12, 2012 an employee was working below other workers without wearing a hard hat, exposing the employee to overhead struck-by hazards. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c) |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2012-05-01 |
Abatement Due Date | 2012-05-08 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-05-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about April 12, 2012 employees were on a roof performing carpentry work without fall protection exposing the employees to a fall hazard of 20.2 feet. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d) |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9427528102 | 2020-07-28 | 0507 | PPP | 4 W HIAWATHA TRL, MOUNT PROSPECT, IL, 60056-3856 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 27 Mar 2025