OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339244154 0521400 2013-07-31 600 WEST LAMM ROAD, FREEPORT, IL, 61032
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2013-07-31
Emphasis L: FALL
Case Closed 2014-09-25

Related Activity

Type Referral
Activity Nr 836588
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2013-08-26
Abatement Due Date 2013-09-20
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-09-17
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated At a jobsite in Freeport, Illinois employees working from aerial lifts ranging from 30 to 35 feet above grade were not using fall proteciton. Abatement documentatioin is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Citation ID 01002
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2013-08-26
Abatement Due Date 2013-09-20
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-09-17
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. At a jobsite in Freeport, Illinois, employees working on a flat commercial roof approximately 28 feet above grade connecting metal decking were not using any method of fall protection. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).