Search icon

METALICO LEGACY ALABAMA, INC.

Branch

Company Details

Entity Name: METALICO LEGACY ALABAMA, INC.
Jurisdiction: Illinois
Entity Type: Corporation - Foreign BCA
Status: Withdrawn
Date Formed: 07 Dec 2004
Branch of: METALICO LEGACY ALABAMA, INC., ALABAMA (Company Number 000-237-602)
Company Number: CORP_63959847
File Number: 63959847
Type of Business: All Inclusive Purpose
Date Status Change: 10 Nov 2015
Place of Formation: ALABAMA

Agent

Name and Address Role Appointment Date
NATIONAL REGISTERED AGENTS, INC., 208 SO LASALLE ST, SUITE 814, CHICAGO, 60604, COOK-NOT IN CITY OF CHICAGO Agent 2015-02-25

President

Name and Address Role
CARLOS E AGUERO 186 NORTH AVE, E CRANFORD NJ 07016 President

Historical Names

Name Change Date
MAYCO INDUSTRIES, INC. 2015-02-06

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMMON 1 Voting Rights 1000 1000000 0.001

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345253645 0524530 2021-04-15 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Monitoring
Scope Partial
Safety/Health Health
Close Conference 2021-04-15
Emphasis N: LEAD
Case Closed 2021-07-01

Related Activity

Type Inspection
Activity Nr 549458
Health Yes
342632478 0524530 2017-09-13 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Monitoring
Scope Partial
Safety/Health Health
Close Conference 2017-09-13
Emphasis L: LEAD, N: LEAD, N: PMETALS
Case Closed 2018-01-30

Related Activity

Type Inspection
Activity Nr 549458
Health Yes
341125797 0524530 2015-12-14 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-12-14
Emphasis N: AMPUTATE
Case Closed 2016-05-09

Related Activity

Type Referral
Activity Nr 1045164
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2016-03-04
Abatement Due Date 2016-03-30
Current Penalty 4851.0
Initial Penalty 6930.0
Final Order 2016-03-23
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Employees using a job made table saw were exposed to unguarded portions of the blade when cutting metal billets.
Citation ID 02001
Citaton Type Other
Standard Cited 19100147 C06 II
Issuance Date 2016-03-04
Abatement Due Date 2016-03-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-23
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: The employer failed to certify periodic inspections of the energy control procedures had been performed.
339395717 0524530 2013-09-06 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-01-10
Emphasis P: SSTARG12, N: SSTARG12, N: LEAD, N: AMPUTATE, L: PIV, L: FALL
Case Closed 2014-03-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100253 E05 V
Issuance Date 2014-01-27
Abatement Due Date 2014-01-31
Current Penalty 1950.0
Initial Penalty 2800.0
Final Order 2014-02-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(e)(5)(v): Hose showing leaks, burns, worn places, or other defects rendering it unfit for service were not repaired or replaced: Employees are exposed to burns while operating a oxygen and fuel torch which contained defects on the hoses such as bubbling, and kinks.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2014-01-27
Abatement Due Date 2014-01-31
Current Penalty 1950.0
Initial Penalty 2800.0
Final Order 2014-02-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employees are exposed to electrical shock due to metal electrical boxes were used as parts to extension cords, and the boxes were not used in accordance with listing or labeling requirements.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 D01
Issuance Date 2014-01-27
Abatement Due Date 2014-02-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-11
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. The lofts in the warehouse were not marked to show the loads approved by a building official.
335494589 0524530 2012-07-31 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2012-07-31
Emphasis L: PRIMETAL, N: LEAD, N: PMETALS
Case Closed 2023-09-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19101025 E03 I
Issuance Date 2012-12-28
Abatement Due Date 2013-02-25
Current Penalty 1768.0
Initial Penalty 2525.0
Final Order 2013-01-23
Nr Instances 1
Nr Exposed 150
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(e)(3)(i): Each employer shall establish and implement a written compliance program to reduce exposures to or below the permissible exposure limit, and interim levels if applicable, solely by means of engineering and work practice controls in accordance with the implementation schedule in paragraph (e)(1). Written plans for these compliance programs shall include at least the following: 1910.1025(e)(3)(ii)(A) A description of each operation in which lead is emitted; e.g. machinery used, material processed, controls in place, crew size, employee job responsibilities, operating procedures and maintenance practices; 1910.1025(e)(3)(ii)(B) A description of the specific means that will be employed to achieve compliance, including engineering plans and studies used to determine methods selected for controlling exposure to lead; 1910.1025(e)(3)(ii)(C) A report of the technology considered in meeting the permissible exposure limit; 1910.1025(e)(3)(ii)(D) Air monitoring data which documents the source of lead emissions; 1910.1025(e)(3)(ii)(E) A detailed schedule for implementation of the program, including documentation such as copies of purchase orders for equipment, construction contracts, etc.; 1910.1025(e)(3)(ii)(F) A work practice program which includes items required under paragraphs (g), (h) and (i) of this regulation; 1910.1025(e)(3)(ii)(G) An administrative control schedule required by paragraph (e)(6), if applicable; 1910.1025(e)(3)(ii)(H) Other relevant information. 1910.1025(e)(3)(iii) Written programs shall be submitted upon request to the Assistant Secretary and the Director, and shall be available at the worksite for examination and copying by the Assistant Secretary, Director, any affected employee or authorized employee representatives. 1910.1025(e)(3)(iv) Written programs must be revised and updated at least annually to reflect the current status of the program.
Citation ID 01002
Citaton Type Serious
Standard Cited 19101025 H01
Issuance Date 2012-12-28
Abatement Due Date 2013-02-25
Current Penalty 1768.0
Initial Penalty 2525.0
Final Order 2013-01-23
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(h)(1): Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead. The change room clean side sink showed positive for lead with a wipe sample, potentially exposing employees to unintended lead contamination.
Citation ID 02001A
Citaton Type Serious
Standard Cited 19101025 C01
Issuance Date 2012-12-28
Abatement Due Date 2021-08-30
Current Penalty 3500.0
Initial Penalty 13860.0
Final Order 2013-01-23
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(c)(1): The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 ug/m(3)) averaged over an 8-hour period. a) On August 22, 2012, Employee #1, working as a maintenance technician, performing work emptying dumpsters, loading skids and changing dross barrels in the baghouse was exposed to lead at a concentration of 64 micrograms per cubic meter of air, approximately 1.6 times the Permissible Exposure Limit (PEL) of 40 micrograms per cubic meter of air (for a 10 hour shift). Measurements were taken during a 496 minute sampling period, where the exposure calculations include a zero increment for the remaining 104 minutes of the 600 minute period. b) On September 11, 2012, Employee #2, working in Cast and Refine, was pouring, pooling, and drossing kettles and was exposed to lead at a concentration of 168 micrograms per cubic meter of air, approximately 3.4 times the PEL of 50 micrograms per cubic meter of air (for an 8 hour shift). Measurements were taken during a 451 minute sampling period, where the exposure calculations include a zero increment for the remaining 29 minutes of the 480 minute period. When employees are exposed to lead for more than eight hours in any work day, the PEL, as a time-weighted average (TWA) for that day shall be reduced according to the following formula: Maximum PEL in micrograms per cubic meter = 400/hours worked in the day. Mayco Industries, Inc. was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.1025(c)(1), which was contained in OSHA Inspection Number 313018483, Citation 1, Item 1a, and was affirmed as a Final Order on 8/18/2011, with respect to a workplace located at 1200 16th Street, Granite City, IL.
Citation ID 02001B
Citaton Type Serious
Standard Cited 19101025 E01 I
Issuance Date 2012-12-28
Abatement Due Date 2021-08-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-01-23
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(e)(1)(i): Where any employee is exposed to lead above the permissible exposure limit for more than 30 days per year, the employer shall implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead in accordance with the implementation schedule in Table I below, except to the extent that the employer can demonstrate that such controls are not feasible. Wherever the engineering and work practice controls which can be instituted are not sufficient to reduce employee exposure to or below the permissible exposure limit, the employer shall nonetheless use them to reduce exposures to the lowest feasible level and shall supplement them by the use of respiratory protection which complies with the requirements of paragraph (f) of this section. On August 22, 2012 and September 11, 2012 an employee working as a maintenance technician, and an Operator A in Cast and Refine were exposed to lead in the following concentrations: Employee #1, a maintenance technician, was exposed to lead at a concentration of 64 micrograms per cubic meter, approximately 1.6 times the Permissible Exposure limit (PEL) of 50 micrograms per cubic meter during a 496 minute sampling period. Employee #2, Operator A in Cast and Refine, was exposed to lead at a concentration of 168 micrograms per cubic meter, approximately 3.4 times the Permissible Exposure limit (PEL) of 50 micrograms per cubic meter during a 451 minute sampling period. All exposures were calculated with a zero increment for the remaining minutes of each 480 or 600 minute period. (See citation 29 CFR 1910.1025(c)(1).) General methods of control that may be applicable in these circumstances include, but are not limited to, the following: 1. Measure local exhaust ventilation for effectiveness and placement in relation to the hazard. 2. Increase local exhaust ventilation as necessary. 3. Increase housekeeping efforts with HEPA vacuuming, wetting floor surfaces to keep down dust, and wet sweeping and wiping of floors and machine surfaces regularly. 4. Repair cracks and openings in walls in order to achieve the optimum flow rate from exhaust ventilation. Mayco Industries, Inc. was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.1025(e)(1)(i), which was contained in OSHA Inspection Number 313018483, Citation 1, Item 1b, and was affirmed as a Final Order on 8/18/2011, with respect to a workplace located at 1200 16th Street, Granite City, IL.
331075291 0524530 2011-10-12 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2011-10-12
Emphasis L: PIV, L: PRIMETAL, N: LEAD, N: PMETALS
Case Closed 2012-01-12

Related Activity

Type Complaint
Activity Nr 78552
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100147 C06 II
Issuance Date 2011-12-29
Abatement Due Date 2012-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-01-26
Nr Exposed 4
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: Employees performing hazardous energy control (lockout/tagout) were periodically inspected and the employer did not maintain documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection.
313018483 0524530 2011-01-28 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2011-05-25
Emphasis L: PRIMETAL, N: LEAD, S: LEAD
Case Closed 2012-12-27

Related Activity

Type Referral
Activity Nr 200844538
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101025 C01
Issuance Date 2011-07-28
Abatement Due Date 2012-03-30
Current Penalty 4410.0
Initial Penalty 6300.0
Nr Instances 4
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101025 E01 I
Issuance Date 2011-07-28
Abatement Due Date 2012-03-30
Nr Instances 4
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
313017717 0524530 2010-12-17 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2011-04-08
Emphasis S: LEAD, L: LEAD, N: LEAD
Case Closed 2011-06-16

Related Activity

Type Complaint
Activity Nr 207141383
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100094 A04 IB
Issuance Date 2011-05-18
Abatement Due Date 2011-05-30
Initial Penalty 2040.0
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2011-05-18
Abatement Due Date 2011-06-20
Initial Penalty 2720.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 05
309292951 0524530 2009-02-26 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2009-03-31
Emphasis S: POWERED IND VEHICLE, N: LEAD, L: LEAD, S: LEAD
Case Closed 2009-09-30

Related Activity

Type Referral
Activity Nr 200843670
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2009-05-26
Abatement Due Date 2009-06-04
Current Penalty 1837.5
Initial Penalty 2625.0
Nr Instances 48
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19100179 J02 I
Issuance Date 2009-05-26
Abatement Due Date 2009-06-05
Current Penalty 787.5
Initial Penalty 1125.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 01
Citation ID 01003
Citaton Type Serious
Standard Cited 19101025 D02
Issuance Date 2009-05-26
Abatement Due Date 2009-07-13
Current Penalty 1837.5
Initial Penalty 2625.0
Nr Instances 4
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 05
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 A02
Issuance Date 2009-05-26
Abatement Due Date 2009-06-12
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19100157 C01
Issuance Date 2009-05-26
Abatement Due Date 2009-05-29
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 01
Citation ID 02003
Citaton Type Other
Standard Cited 19101025 L01 I
Issuance Date 2009-05-26
Abatement Due Date 2009-06-12
Nr Instances 7
Nr Exposed 7
Related Event Code (REC) Referral
Gravity 01
303818553 0524530 2003-07-09 1200 16TH STREET, GRANITE CITY, IL, 62040
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2003-07-09
Emphasis S: LEAD, L: LEAD, N: LEAD
Case Closed 2003-12-10

Related Activity

Type Complaint
Activity Nr 204150387
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2003-11-07
Abatement Due Date 2003-12-10
Current Penalty 910.0
Initial Penalty 1300.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C05 I
Issuance Date 2003-11-07
Abatement Due Date 2003-12-10
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 02
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2003-11-07
Abatement Due Date 2003-12-10
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 02