Search icon

WES & SON'S CONSTRUCTION INC.

Company Details

Entity Name: WES & SON'S CONSTRUCTION INC.
Jurisdiction: Illinois
Entity Type: Corporation - Domestic BCA
Status: Goodstanding
Date Formed: 22 Jan 2007
Company Number: CORP_65339528
File Number: 65339528
Type of Business: All Inclusive Purpose
Place of Formation: ILLINOIS

Agent

Name and Address Role Appointment Date
WIESLAW CHRAPCZYNSKI, 707 WILDWOOD LN, STREAMWOOD, 60107, COOK-NOT IN CITY OF CHICAGO Agent 2007-01-22

President

Name and Address Role
WIESLAW CHRAPCZYNSKI 707 WILDWOOD LN STREAMWOOD IL, 60107 President

Secretary

Name and Address Role
WIESLAW CHRAPCZYNSKI 707 WILDWOOD LN STREAMWOOD IL, 60107 Secretary

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMM No data Voting Rights 1000 1000000 No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345923072 0524200 2022-04-27 121 N. WASHINGTON AVE., PARK RIDGE, IL, 60068
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-04-27
Emphasis L: FALL, P: FALL
Case Closed 2023-10-27

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2022-09-07
Abatement Due Date 2022-09-30
Current Penalty 2486.0
Initial Penalty 2486.0
Final Order 2022-10-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On April 27, 2022, employees were exposed to eye injury while operating a pneumatic roofing gun without eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2022-09-07
Abatement Due Date 2022-09-30
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2022-10-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On April 27, 2022, employees were exposed to the hazard of falling while working from a ladder jack scaffold platform elevated approximately 18 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 G01 III
Issuance Date 2022-09-07
Abatement Due Date 2022-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board: a) On April 27, 2022, employees were exposed to fall hazards of approximately 18 feet to the ground while working from a crawling board. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260452 M01
Issuance Date 2022-09-07
Abatement Due Date 2022-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance: a) On April 27, 2022, employees were working from a crawling board that did not extend from the roof peak to the roof eave. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260452 M02
Issuance Date 2022-09-07
Abatement Due Date 2022-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability): a) On April 27, 2022, employees were working from a crawling board that was not secured to the roof by the ridge hook. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
340121672 0524200 2014-12-04 1306 CORA AVE., DES PLAINES, IL, 60016
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-12-04
Case Closed 2015-04-14

Related Activity

Type Referral
Activity Nr 925647
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260416 A01
Issuance Date 2015-03-18
Abatement Due Date 2015-03-30
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2015-04-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Employees were exposed to electrical shock while working in close proximity to a 120/240 volt power line. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2015-03-18
Abatement Due Date 2015-03-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): a) Employees were exposed to electrical hazards while erecting, dismantling, and working from a ladder jack scaffoldwithin 3 feet of a 120/240 volt power line. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261053 B12
Issuance Date 2015-03-18
Abatement Due Date 2015-03-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails: a) Employees were exposed to electrical shock while working from an aluminum extension ladder in close proximity to a 120/240 volt power line. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
313064511 0524200 2009-03-13 1028 HEATHERFIELD LANE, GLENVIEW, IL, 60025
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2009-03-13
Emphasis S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT, L: FALL
Case Closed 2009-07-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2009-04-09
Abatement Due Date 2009-04-15
Current Penalty 600.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 2
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2009-04-09
Abatement Due Date 2009-04-15
Current Penalty 240.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 2
Gravity 02

Date of last update: 13 Feb 2025