Entity Name: | PRIME PLUMBING SERVICES, INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Goodstanding |
Date Formed: | 31 Mar 2010 |
Company Number: | CORP_67007204 |
File Number: | 67007204 |
Type of Business: | All Inclusive Purpose |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
ALEXANDER POLYAKOV, 20663 N HORATIO BLVD, LINCOLNSHIRE, 60069, LAKE | Agent | 2018-09-17 |
Name and Address | Role |
---|---|
ALEX POLYAKOV 20663 N. HORATIOBLVD LINCOLNSHIRE IL 60069 | President |
Name | Type | Effective Date | Cancellation Date | Cancellation Type | Last Renewal Date |
---|---|---|---|---|---|
PPSR,INC | Assume Name | 2022-03-09 | No data | No data | No data |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMMON | No data | Voting Rights | 1000 | 100000 | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341409589 | 0524200 | 2016-04-07 | 1425 GARDEN ST., PARK RIDGE, IL, 60068 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1138391 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1140901 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2016-06-01 |
Abatement Due Date | 2016-06-07 |
Current Penalty | 900.0 |
Initial Penalty | 2040.0 |
Final Order | 2016-06-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On April 07, 2016, employees performing plumbing work were exposed to falls of approximately 6.5 feet from an unprotected open hole leading down into the basement of the house. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 A02 |
Issuance Date | 2016-06-01 |
Abatement Due Date | 2016-06-07 |
Current Penalty | 0.0 |
Initial Penalty | 1360.0 |
Final Order | 2016-06-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and steps were not parallel, level, and uniformly spaced when the ladder was in position for use: a) On April 07, 2016, the employer provided for employee use a jobsite made ladder in order to access and egress the basement. The jobsite ladder's rungs were not evenly spaced. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 A01 II |
Issuance Date | 2016-06-01 |
Abatement Due Date | 2016-06-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-06-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(a)(1)(ii): Job-made ladder was not built in conformance with the applicable provisions of Appendix A: a) Employees were using a job-made ladder to access the basement. The ladder was not built in conformance with Appendix A which references American National Standards Institute (ANSI), A 14.4-1979-Safety Requirements for Job-Made Ladders. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2016-06-01 |
Abatement Due Date | 2016-06-07 |
Current Penalty | 800.0 |
Initial Penalty | 0.0 |
Final Order | 2016-06-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) On April 07, 2016, an employees were performing plumbing work utilizing an A-frame step ladder to provide access/ egress to a basement. The employees standing on the top step of a 6 foot A-frame ladder. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7465347309 | 2020-04-30 | 0507 | PPP | 20663 N HORATIO BLVD, PRAIRIE VIEW, IL, 60069-9614 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2257198507 | 2021-02-20 | 0507 | PPS | 20663 N Horatio Blvd, Prairie View, IL, 60069-9614 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 13 Feb 2025