344436704
|
0524200
|
2019-11-08
|
405 RIDGE CIR., STREAMWOOD, IL, 60107
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-11-08
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-02-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2020-01-27 |
Current Penalty |
1500.0 |
Initial Penalty |
2545.0 |
Final Order |
2020-02-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On November 8, 2019, the employer provided an aluminum ladder used by employees to gain access to the roof and did not have the side rails extended at least 3 feet above the surface. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2020-01-27 |
Abatement Due Date |
2020-01-31 |
Current Penalty |
5000.0 |
Initial Penalty |
7634.0 |
Final Order |
2020-02-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On November 8, 2019, employees were exposed to fall hazards of approximately 8.3 feet while performing roofing work to an existing home. MJK Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10), which was contained in OSHA inspection number 1248598, citation number 1, item number 1 and was affirmed as a final order on September 21, 2017, with respect to a workplace located at 411 Cass Ave., Westmont, IL 60559. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260503 B01 |
Issuance Date |
2020-01-27 |
Abatement Due Date |
2020-02-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-02-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written certification record: a) On or about November 8, 2019, the employer did not prepare written certification records related to employee fall protection training. |
|
|
342485984
|
0521400
|
2017-07-17
|
411 CASS AVE., WESTMONT, IL, 60559
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-07-17
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-09-28
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2017-08-21 |
Current Penalty |
2300.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-21 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. On or about July 17, 2017, employees engaged in roofing tear off operations were exposed to a 16 foot fall when the employer failed to ensure fall protection was utilized. No abatement certification or documentation is required for this item. |
|
|
315298612
|
0524200
|
2011-03-01
|
1585 ELLINWOOD, DES PLAINES, IL, 60016
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-03-01
|
Emphasis |
S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: FALL
|
Case Closed |
2011-12-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2011-03-29 |
Abatement Due Date |
2011-04-04 |
Current Penalty |
1750.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
|