344688205
|
0524200
|
2020-03-10
|
3228 W. PALMER ST., CHICAGO, IL, 60647
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-03-10
|
Emphasis |
N: TRENCH, P: TRENCH
|
Case Closed |
2023-02-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 D |
Issuance Date |
2020-03-16 |
Current Penalty |
1000.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-04-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(d): Employees exposed to public vehicular traffic were not provided with a warning vest or other suitable garments marked with or made of reflectorized or high-visibility material: a) On March 10, 2020, an employee that was exposed to public vehicular traffic was not wearing high-visibility vest during trenching operations. No abatement certification or documentation is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2020-03-16 |
Abatement Due Date |
2020-03-20 |
Current Penalty |
3000.0 |
Initial Penalty |
4048.0 |
Final Order |
2020-04-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): a) On March 10, 2020, an employee was not protected from the hazard of cave-in while working in a trench measuring approximately 6.5 feet in depth. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2020-03-16 |
Abatement Due Date |
2020-03-20 |
Current Penalty |
1000.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-04-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On Mach 10, 2020, a ladder used by employees to access and egress the trench did not have its side rails extended at least 3 feet above the ground. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2020-03-16 |
Abatement Due Date |
2020-03-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-04-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On March 10, 2020, employees were using a fly section of the extension ladder to access and egress a trench. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2020-03-16 |
Abatement Due Date |
2020-03-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-04-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) On March 10, 2020, a ladder used by employees to access and egress the trench had structural defects, such as, damaged rails. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
|
336189782
|
0524200
|
2012-09-07
|
2726 N. MARSHFIELD AVE., CHICAGO, IL, 60614
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-07
|
Emphasis |
N: TRENCH
|
Case Closed |
2013-09-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
2012-10-04 |
Abatement Due Date |
2012-10-05 |
Current Penalty |
2640.0 |
Initial Penalty |
5280.0 |
Final Order |
2012-11-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): a) Employees were not protected from cave-in hazards while working in a trench measuring up to approximately 5 feet 10 inches in depth. PJS Excavating, Sewer, & Water, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.652(a)(1) which was contained in OSHA inspection number 314817412, citation 2, item 1, issued on October 20, 2010 and became final order on or about November 02, 2010 with respect to a workplace located at 1324 S. Fairview Ave. Park Ridge, IL 60068. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |
|
|
314817412
|
0524200
|
2010-09-21
|
1324 S. FAIRVIEW, PARK RIDGE, IL, 60068
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-09-21
|
Emphasis |
S: TRENCHING, S: COMMERCIAL CONSTR, N: TRENCH
|
Case Closed |
2012-10-09
|
Related Activity
Type |
Referral |
Activity Nr |
202952925 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2010-10-20 |
Abatement Due Date |
2010-10-25 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260652 A01 |
Issuance Date |
2010-10-20 |
Abatement Due Date |
2010-11-01 |
Current Penalty |
4250.0 |
Initial Penalty |
7000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|