Search icon

J MUNOZ CONSTRUCTION CORPORATION

Company Details

Entity Name: J MUNOZ CONSTRUCTION CORPORATION
Jurisdiction: Illinois
Entity Type: Corporation - Domestic BCA
Status: Reinstated
Date Formed: 23 Apr 2012
Date of Dissolution: 13 Sep 2024
Company Number: CORP_68273552
File Number: 68273552
Type of Business: All Inclusive Purpose
Date Status Change: 13 Sep 2024
Place of Formation: ILLINOIS

Agent

Name and Address Role Appointment Date
JOSE A MUNOZ, 2126 N GREEN VALLEY LN, ROUND LAKE BEACH, 60073, LAKE Agent 2012-04-23

President

Name and Address Role
JOSE MU�OZ 2720 EDINA BLVD ZION IL, 60099 President

Secretary

Name and Address Role
JOSE MUNOZ 2720 EDINA BLVD ZION IL, 60099 Secretary

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMMON No data Voting Rights 1000 1000000 No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344368030 0521400 2019-10-09 932 JESSAMINE DR., OSWEGO, IL, 60543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-10-09
Emphasis L: FALL, P: FALL
Case Closed 2020-06-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2019-10-28
Current Penalty 1100.0
Initial Penalty 1705.0
Final Order 2019-11-12
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On or about October 9, 2019, employees conducting siding installation at a residential single-family property were exposed to struck-by hazards while working on two levels when the employer failed to ensure that hard hats were utilized. No abatement certification or documentation is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2019-10-28
Current Penalty 2599.0
Initial Penalty 3978.0
Final Order 2019-11-12
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. On or about October 9, 2019, employees performing siding installation from a pump-jack scaffold at a residential single family property were exposed to a fall of approximately 16.6 feet when the employer failed to ensure that fall protection was utilized. No abatement certification or documentation is required for this item.