Search icon

PR MASONRY, INC.

Company Details

Entity Name: PR MASONRY, INC.
Jurisdiction: Illinois
Entity Type: Corporation - Foreign BCA
Status: Revoked
Date Formed: 11 Feb 2016
Company Number: CORP_70460823
File Number: 70460823
Type of Business: All Inclusive Purpose
Date Status Change: 08 Jul 2022
Place of Formation: IOWA

Agent

Name and Address Role Appointment Date
MEREDITH HUMMEL, 222 S FRONT ST, REYNOLDS, 61279, SANGAMON Agent 2016-02-11

President

Name and Address Role
PAT RUPP 2654 W CENTRAL PARK DAVENPORT IA 52804 President

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMMON No data Voting Rights 10000 6668000 10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341138246 0524500 2015-12-22 1210 N HENDERSON STREET, GALESBURG, IL, 61401
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-12-22
Emphasis L: FALL, P: FALL
Case Closed 2016-04-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 1500.0
Initial Penalty 2800.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): The supported poles, legs, posts, frames and uprights did not bear on base plates and mud sills or other adequate firm foundation: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks because the frame scaffold poles and uprights did not bear on base plates.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 1500.0
Initial Penalty 2800.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral pre-fabricated scaffold access, or direct access from another structure, personnel hoist, or similar surface were not used: An employee patching concrete blocks was exposed to a fall hazard when the frame scaffold was used to gain access to the working platform and a suitable means of access was not provided.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 1500.0
Initial Penalty 2800.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels was not fully planked or decked between the front uprights and the guardrail supports: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks and the working level was not fully decked.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Fabricated frame scaffold frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks because the scaffolding did not have diagonal bracing that secured all the vertical members together laterally.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who is involved in erecting, disassembling, moving, operation, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks and the employer had not provided training to the employee on the nature of the scaffold hazards and the design criteria and the intended use of the scaffold.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 1500.0
Initial Penalty 2800.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks because two of the tubular welded frame scaffold poles were not connected.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-01-19
Abatement Due Date 2016-03-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: An employee was exposed to a fall hazard and scaffold collapse while patching concrete blocks because the scaffolding was not erected under the direction of someone acting in the capacity of a competent person before employees were allowed to access the scaffold.

Date of last update: 10 Mar 2025

Sources: Illinois Office of the Secretary of State