Entity Name: | MARCOS GARIBAY CONSTRUCTION INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Dissolved |
Date Formed: | 10 Jun 2016 |
Date of Dissolution: | 11 Nov 2022 |
Company Number: | CORP_70729695 |
File Number: | 70729695 |
Type of Business: | All Inclusive Purpose |
Date Status Change: | 11 Nov 2022 |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
TRACY SMITH, 3118 JAMES AVE, WINTHROP HARBOR, 60096, LAKE | Agent | 2016-06-10 |
Name and Address | Role |
---|---|
MARCOS GARIBAY 11989 29TH ST BEACH PARK, IL 60099 | President |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMMON | No data | Voting Rights | 100 | 100000 | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345455885 | 0524200 | 2021-08-02 | 898 DEERFIELD ROAD, HIGHLAND PARK, IL, 60035 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B04 II |
Issuance Date | 2021-08-12 |
Abatement Due Date | 2021-08-18 |
Current Penalty | 2650.0 |
Initial Penalty | 3511.0 |
Contest Date | 2021-09-29 |
Final Order | 2022-02-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: a) On or about August 2, 2021, the cutting blade on an electric miter saw was not guarded when used to cut lumber at the site. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2021-08-12 |
Abatement Due Date | 2021-08-18 |
Current Penalty | 2650.0 |
Initial Penalty | 4096.0 |
Contest Date | 2021-09-29 |
Final Order | 2022-02-07 |
Nr Instances | 5 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about August 2, 2021, employees were exposed to the hazard of falling approximately 20 feet from a second story deck to the exterior of the building while performing carpentry work without fall protection. b) On or about August 2, 2021, employees were exposed to the hazard of falling approximately 10 feet from a second story deck to the interior of the building while performing carpentry work without fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. |