Search icon

INTERNATIONAL BONDED COURIERS, INC.

Branch

Company Details

Entity Name: INTERNATIONAL BONDED COURIERS, INC.
Jurisdiction: Illinois
Entity Type: Corporation - Foreign BCA
Status: Goodstanding
Date Formed: 24 Oct 2016
Branch of: INTERNATIONAL BONDED COURIERS, INC., FLORIDA (Company Number 668892)
Company Number: CORP_70864908
File Number: 70864908
Type of Business: All Inclusive Purpose
Place of Formation: FLORIDA

Agent

Name and Address Role Appointment Date
RICHARD CRAI, 9740 W FOSTER AVE, ROSEMONT, 60018, COOK-NOT IN CITY OF CHICAGO Agent 2016-10-24

Secretary

Name and Address Role
RICHARD CRAI Secretary

President

Name and Address Role
JOSEPH COSTIGAN, 152-01 ROCKAWAY BLVD, JAMAICA NY 11434 President

Shares

Class Series Voting Rights Authorized Shares Issued Shares Par Value
COMMON No data Voting Rights 30000 10512000 No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347489007 0524200 2024-05-14 9740 W FOSTER AVE., ROSEMONT, IL, 60018
Inspection Type Referral
Scope Records
Safety/Health Safety
Close Conference 2024-08-26
Case Closed 2024-11-26

Related Activity

Type Referral
Activity Nr 2163859
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19040041 A01 I
Issuance Date 2024-08-26
Abatement Due Date 2024-09-20
Current Penalty 1612.8
Initial Penalty 2304.0
Final Order 2024-09-23
Nr Instances 1
Nr Exposed 35
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.41(a)(1)(i):The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A, Summary of Work-Related Injuries and Illnesses, to OSHA or OSHA's designee by the specified date: a) International Bonded Couriers, Inc. located at 9740 W. Foster Avenue, in Rosemont, IL - On or about May 9, 2024, the employer did not electronically submit information from their OSHA Form 300A or equivalent for calendar year 2023, by the specified date of March 2, 2024. The employer, in NACIS code 492110, had 35 employees in calendar year 2023.
347472698 0524200 2024-05-09 9740 W FOSTER AVE., ROSEMONT, IL, 60018
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-05-09
Emphasis L: PIV, N: FALL, N: WAREHOUSE23, P: WAREHOUSE23
Case Closed 2024-11-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100028 B01 I
Issuance Date 2024-09-30
Current Penalty 8000.0
Initial Penalty 16131.0
Final Order 2024-10-24
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): (a) On or about May 9, 2024, the employer did not ensure that employees unloading Unit Load Devices (ULDs) were not exposed to unprotected sides or edges that are 4 feet or more above a lower level. Employees were standing on top of boxes approximately 7 feet in height during break down of the ULDs at the worksite. No abatement certification or documentation is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 2024-09-30
Abatement Due Date 2024-10-18
Current Penalty 6000.0
Initial Penalty 11524.0
Final Order 2024-10-24
Nr Instances 1
Nr Exposed 30
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) On or about May 8, 2024, doors designated as emergency exits were locked on the west end of the facility located at 9740/9742 W. Foster Ave., Chicago, IL 60656. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2024-09-30
Current Penalty 4700.0
Initial Penalty 9218.0
Final Order 2024-10-24
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) On or about May 9, 2024, the employer did not ensure that employees operating Linde MT12 and MT18 electric pallet trucks were competent to operate a powered industrial truck by training and evaluating the operators in the safe use of electric pallet trucks. No abatement certification or documentation is required for this item.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100178 Q07
Issuance Date 2024-09-30
Current Penalty 6650.0
Initial Penalty 13828.0
Final Order 2024-10-24
Nr Instances 3
Nr Exposed 35
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) On and before May 9, 2024, the employer did not ensure that employees that operated the Linde MT12 and MT18 electric pallet jacks performed evaluations on a daily basis before each shift at the facility. (b) On and before May 9, 2024, the employer did not ensure that employees that operated the Doonsan B50X-7, S/N: FBB09-1390-00165, performed evaluations on a daily basis before each shift at the facility. (c) On and before May 9, 2024, the employer did not ensure that employees that operated the Doonsan BC32S-7, S/N: FBA1D-1360-00144, performed evaluations on a daily basis before each shift at the facility. No abatement certification or documentation is required for this item.

Date of last update: 24 Apr 2025

Sources: Illinois Office of the Secretary of State