Entity Name: | J&A ELITE CONSTRUCTION, INC. |
Jurisdiction: | Illinois |
Entity Type: | Corporation - Domestic BCA |
Status: | Goodstanding |
Date Formed: | 08 Feb 2022 |
Company Number: | CORP_73626218 |
File Number: | 73626218 |
Type of Business: | All Inclusive Purpose |
Place of Formation: | ILLINOIS |
Name and Address | Role | Appointment Date |
---|---|---|
ANTHONY VELA, 4901 W 115TH ST STE A, ALSIP, 60803, COOK-NOT IN CITY OF CHICAGO | Agent | 2024-02-29 |
Name and Address | Role |
---|---|
ANTHONY VELA 9524S KOLIN AVE OAKLAWN IL | President |
Name and Address | Role |
---|---|
ANTHONY VELA 9524S KOLIN AVE OAKLAWN IL | Secretary |
Class | Series | Voting Rights | Authorized Shares | Issued Shares | Par Value |
---|---|---|---|---|---|
COMMON | No data | Voting Rights | 1000 | 100000 | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347504912 | 0521700 | 2024-05-22 | 15609 PARK STATION BLVD., ORLAND PARK, IL, 60462 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1750498 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2024-09-17 |
Current Penalty | 5650.0 |
Initial Penalty | 11292.0 |
Final Order | 2024-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated. a) On or about May 22, 2024, at the above addressed jobsite, an employee performing commercial carpentry operations from a SkyJack SJ86T mobile elevating work platform, at an elevation of approximately forty (40) feet, was not connected to the boom or basket, thereby exposing the employee to the hazards associated with falls. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2024-09-17 |
Abatement Due Date | 2024-09-23 |
Current Penalty | 5650.0 |
Initial Penalty | 11292.0 |
Final Order | 2024-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about May 22, 2024, at the above addressed jobsite, an employee performing carpentry operations from the roof was exposed to a fall, of approximately forty (40') feet, created by the presence of unprotected sides. |
Date of last update: 13 Mar 2025