Search icon

C.G.O CONSTRUCTION LLC

Company Details

Entity Name: C.G.O CONSTRUCTION LLC
Jurisdiction: Illinois
Entity Type: Limited Liability Company
Status: Goodstanding
Date Formed: 14 Oct 2015
Company Number: LLC_05469155
File Number: 05469155
Type of Management: Manager Managed
Date Status Change: 17 Sep 2024
Address 325 CLARK ST, AURORA, 60505, IL
Place of Formation: ILLINOIS

Agent

Name and Address Role Appointment Date
LISBETH GUERRERO, 325 CLARK ST, AURORA, 60505 Agent 2015-10-14

Manager

Name and Address Role Appointment Date
PUBLIC, OMAR CONTRERAS, 325 CLARK ST, AURORA, IL, 60505 Manager 2015-10-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347987067 0521400 2025-01-17 133 SOUTH PARK AVE., HINSDALE, IL, 60521
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2025-01-17
Emphasis N: FALL, P: FALL
346646003 0521400 2023-04-20 215 N. WASHINGTON, HINSDALE, IL, 60521
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-04-20
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 II
Issuance Date 2023-05-26
Abatement Due Date 2023-09-01
Current Penalty 2500.0
Initial Penalty 4420.0
Final Order 2023-06-30
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5). On or about April 20, 2023, an employee was allowed to operate a powered industrial fork truck prior to receiving the required training, exposing employees to struck- by hazards. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2023-05-26
Abatement Due Date 2023-06-12
Current Penalty 5900.0
Initial Penalty 10313.0
Final Order 2023-06-30
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system: On or about April 20, 2023, employees performing framing operations on the upper level at a single-family property were exposed to a 13.6 foot fall when the employer failed to ensure that fall protection was utilized. C.G.O. Construction LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1316461, citation number 1, item number 1 and was affirmed as a final order on August 6, 2018, with respect to a workplace located at 4603 Oakwood Ave. Downers Grove, IL 60515. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
343164612 0521400 2018-05-15 4603 OAKWOOD AVE., DOWNERS GROVE, IL, 60515
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-05-15
Emphasis L: FALL, P: FALL
Case Closed 2022-09-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-05-25
Current Penalty 2400.0
Initial Penalty 3880.0
Final Order 2018-08-06
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about May 15, 2018, employees performing framing operations on the upper level at a single-family property were exposed to a 13.2 foot fall when the employer failed to ensure that fall protection was utilized. No abatement certification or documentation is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-05-25
Current Penalty 1200.0
Initial Penalty 2772.0
Final Order 2018-08-06
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about May 15, 2018, employees were exposed to a fall hazard of 13.2' when the employer failed to ensure the siderails of the ladder used to gain access extended 3' above the landing surface to which the ladder was used to gain access. No abatement certification or documentation is required for this item.

Date of last update: 13 Feb 2025

Sources: Illinois Office of the Secretary of State