Search icon

SANDOVAL ROOFING LLC

Company Details

Entity Name: SANDOVAL ROOFING LLC
Jurisdiction: Illinois
Entity Type: Limited Liability Company
Status: Goodstanding
Date Formed: 27 Jul 2016
Company Number: LLC_05909287
File Number: 05909287
Type of Management: Member Managed
Date Status Change: 06 Sep 2024
Address 129 S 16TH AVE, MAYWOOD, 60153, IL
Place of Formation: ILLINOIS

Agent

Name and Address Role Appointment Date
ARMANDO SANDOVAL, 129 S. 16TH ST., MAYWOOD, 60153 Agent 2018-04-24

Manager

Name and Address Role Appointment Date
SANDOVAL, ARMANDO, 129 S 16TH AVE, MAYWOOD, IL, 60153 Manager 2024-09-06
SANDOVAL, HERMILIO, 129 S 16TH AVE, MAYWOOD, IL, 60153 Manager 2024-09-06

License

License Type License Number Status License Code License Description Business Activity Date Issued Effective Date Expiration Date
ROOFING CONTRACTOR 104017592 No data No data LICENSED ROOFING CONTRACTOR No data 2017-05-12 2023-11-21 2025-12-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347244022 0524200 2024-01-29 233 SPRUCE RD, NORTHBROOK, IL, 60062
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-01-29
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-04-16
Current Penalty 1850.0
Initial Penalty 3687.0
Final Order 2024-05-02
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On January 29, 2024, employees were exposed to eye injury while operating a pneumatic nail gun without eye protection during roofing work. No abatement certification or documentation is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-04-16
Current Penalty 4000.0
Initial Penalty 6452.0
Final Order 2024-05-02
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On January 29, 2024, employees performing roofing work were exposed to fall hazards of approximately 22 feet. No abatement certification or documentation is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 D06 I
Issuance Date 2024-04-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-02
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(i): Snaphooks were engaged directly to webbing, rope or wire rope: a) On January 29, 2024, snaphooks were connected to the nylon webbing of body harnesses used for fall protection on pitched roof surfaces. No abatement certification or documentation is required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260502 D17
Issuance Date 2024-04-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-02
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) On January 29, 2024, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces. No abatement certification or documentation is required for this item.

Date of last update: 13 Feb 2025

Sources: Illinois Office of the Secretary of State